AHD-RB6

Electronic Circuit Breaker (ECB)

Protection – Switching - Dimming

The AHD-RB6 is an electronic circuit breaker (ECB) for six channels with CAN-Bus connection for connecting, controlling and monitoring of electrical loads up to 16A / 24VDC per channel. The device switches all load circuits bipolar. If required, four channels on each device can be connected to two channels increasing the nominal current to 28A for each double channel.

The maximum current can be separately adjusted for each channel to 6.3A, 10A or 16A, providing according protection for all cables with corresponding dimensioning. The terminals for the power input can handle a current of 125A. The current of each channel is measured separately, enabling the AHD-RB6 to be used for example as a power management device.The recorded current values can be evaluated over CAN bus and visualized for example on our displays and monitors.

In case of a CAN system or processor failure each channel can be manually set with the built-in switches without affecting the safety function.

Each channel can be configured separately for dimming of lighting, where a different dimming value can be assigned to each channel over CAN bus (display) or by pushbutton.


If a pushbutton is used for dimming, a short pressing of the button switches the lighting on or off, while pressing and holding the button activates the dimming function (dimming from bright to dark or from dark to bright, respectively).

Two AHD-RB6 in a row can serve as security switches: This is best explained in a short example.
Channel 1 of the first AHD-RB6 controls a cooler fan. If this channel is switched off, channel 1 of the second circuit breaker, controlling the backup cooler fan, is automatically switched on, ensuring a constant cooling.

Product Features

  • Nominal current up to 16A per channel / 28A for connected channels (Slave channel)
  • Bipolar switching of all channels
  • Operating voltage 24VDC (-30%/+25%)
  • 6 channels output; 6 channels input, e.g. for light switches, level switches or other contacts, independently configurable
  • Free configuration with the Böning DeviceConfig tool
  • Separate current measurement for each channel (< 50mA resolution)
  • Visualization of all relevant data e.g. on our displays possible
  • Dimmer function for lighting control
  • Staus LEDs for each channel
  • Watchdog supervision
  • Wire break supervision, undercurrent and overcurrent detection
  • 3-step current limit setting with rotary switches
  • Maximum security by redundant switch circuits
  • Protection against overvoltage, short-circuit, overload and overheating
  • Easy and cost-effective installation with patch cables for CAN bus
  • Soft switching of lamps for longer durability (pulse width modulation)
  • Grouping of channels, e.g.for lighting control
  • Programmable lag time for outputs
  • Operating temperature range allows installation in any location, including engine rooms
  • Significant reduction of cabling and costs due to decentralized installation
  • Stand-Alone device operation possible with pushbuttons / switches
  • Connection to NMEA 2000 network (upon request)