AHD-WNL

Logig Unit

The AHD-WNL is a black-box PC with a closed operating system that has been specifically designed as a logging computer with logging functionality. The system enables the storage of system-relevant logging data and records measurement values and events captured via the ship’s network of the connected alarm and monitoring system. All collected data can be displayed on the ship system’s panel PCs or displays or exported in various formats. Data output typically occurs within the graphical system configuration through the embedding of so-called “logging pages.” These are created within the project-specific visualization and allow for the implementation of predefined query functions according to customer requirements. Frequently recurring queries of important data points or sensors can thus be executed easily and conveniently. Alternatively, there are two other ways to retrieve the data using external tools:

  • With “AHD Charting,” the values logged in the AHD-WNL can be read out using a computer or laptop, displayed graphically, and exported as a Microsoft Excel file (xls). The querying PC is connected to the customer’s network (LAN-2) for this purpose. Frequently used settings can be saved as profiles within AHD Charting.
  • With “WNL Exporter,” the logged values are exported directly to an Excel file. Fixed timestamps can be defined, which enables a better comparison of values based on a common time reference. Furthermore, data export can be automated on a cyclical basis using a batch file or a task scheduler.

AHD-WNL processes all relevant information and transfers the measurement points and events assigned in the configuration to a solid-state drive (SSD). It can store up to 50 million measurement values and 100,000 events. The built-in battery pack ensures that the PC shuts down properly even in the event of a sudden power failure.

  • Compact PC with a closed operating system and built-in software for recording selected logging data
  • SSD hard drive and passive cooling system (no moving parts)
  • DVI-I output (1920x1080 pixels)
  • 2 x LAN (ship network and optional customer network)
  • 4 x USB 2.0, 1 x RS232 (serial COM1)
  • 2 x digital inputs (option external shutdown)
  • 2 x digital output (option)
  • Internal battery pack ensures backup operation for approx. 10 min
  • User-friendly software for calling up, viewing, and export of logging data
Kategorie:
Alarm Systems and Display Panels
Keywords:
WNL
No images found.

Certificates

Keine Dateien vorhanden.